Temperature Cycling Chamber Air - to -Air |
|
|
|
|
|
 |
Temp. Range : -65°C to + 200°C |

Vibration Test System |
|
|
|
|
|
 |
Control Tolerance: ± 2 °C |
|
|
|
|
|
|
|
|
|
 |
|
Thermal Shock Chamber Liquid-to-Liquid |
|
|
|
|
|
 |
Two tanks (Hot and Cold Bath) |
|
|
|
|
|
 |
Temperature Range:-73°C to +200 °C |
|
|
|
|
|
 |
Control tolerance:±2 °C. |
|
|
|
|
|
|
|
|
|
 |
|
Vibration Test System |
|
|
|
|
|
 |
Rated Force: 400 Kgf |
|
|
|
|
|
 |
Frequency Range: 5Hz to 3000Hz. |
|
|
|
|
|
 |
Acceleration Range : upto 8g at 10Kg load
upto 6.5g at 20Kg load |
|
|
|
|
|
|
|
|
|
 |
|
Damp Heat Cycling Chamber |
|
|
|
|
|
|
 |
Temperature Range:-37 °C to +190 °C |
|
|
|
|
|
 |
Relative Humidity: 20% to 95%. |
|
|
|
|
|
|
|
|
|
 |
|
Highly Accelerated Stress Test |
|
|
|
|

|
Temperature Range +50°C to +
170°C with Bias capability |

Seal Test Pressurization Chamber |
|
|
|
|
|
 |
Relative Humidity : 50% to
100% |
|
|
|
|
|
|
|
|
|
 |
|
Seal Test Pressurization Chamber |
|
|
|
|
 |
Pressure Range : 0 to 140 psi (g) |
|
|
|
|
|
 |
Helium for fine leak & Per-fluorocarbon liquid for gross leak |
|
|
|
|
|
|
|
|
|
 |
|
Fine Leak Tester |
|
|
|
|
|
 |
For leaks from 2.0 x 10-10 to 10 atm/cc/sec, without LN2 use. |
|
|
|
|
|
|
|
|
|
 |
|
Gross Leak Tester |
|
|
|
|
|
 |
Operating Temperature:+125 °C |
|
|
|
|
|
 |
Leak Range:0 to 2800 microgram |
|
|
|
|
|
 |
Non Dispersive IR Detector. |
|
|
|
|
|
|
|
|
|
 |
|
Burn - in Chamber |
|
|
|
|
|
 |
Temper Range: +50 °C to 200 °C |

Burn-In System |
|
|
|
|
|
 |
Both static and Dynamic Burn in Facility |
|
|
|
|
|
 |
Bias Voltage Range : ±5V to 30V, power upto 200W |
|
|
|
|
|
 |
Signal Frequency: upto 10MHz |
|
|
|
|
|
|
|
|
|
 |
|
High Temperature Storage |
|
|
|
|
|
 |
Temperature Range : 25°C to 200 °C |
|
|
|
|
|
|
|
|
|
 |
|
Centrifuge Test Systems (Constant
Acceleration Tester.) |
|
|
|
|
|
 |
Acceleration upto 40000g. |
|
|
|
|
|
|
|
|
|
 |
|
Mechanical Shock Tester |
|
|
|
|
|
 |
1500g at 0.5 ms to 1.0ms. |
|
|
|
|
|
|
|
|
|
 |
|
Salt Spray / Corrosion Tester |
|
|
|
|
|
 |
Air pressure operation at 12 to 15 psig at chamber temperature
of +35 °C. |
|
|
|
|
|
|
|
|
|
 |
|
ESD Tester |
|
|
|
|
|
 |
Voltage Range: 25V to 16KV |
|
|
|
|
|
|
|